| DEPTH OF TRENCH (FEET) |
WALES | HYDRAULIC CYLINDERS | TIMBER UPRIGHTS | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| VERTICAL SPACING (FEET) |
*SECTION MODULUS (IN³) |
WIDTH OF TRENCH (FEET) | MAX. HORIZ. SPACING (ON CENTER) |
||||||||
| UP TO 8 | OVER 8 UP TO 12 | OVER 12 UP TO 15 | SOLID SHEET |
2 FT. | 3 FT. | ||||||
| HORIZ. SPACING |
CYLINDER DIAMETER |
HORIZ. SPACING |
CYLINDER DIAMETER |
HORIZ. SPACING |
CYLINDER DIAMETER |
||||||
| OVER 5 UP TO 10 |
4 | 3.5 | 8.0 | 2 IN. | 8.0 | 2 IN. |
8.0 | 3 IN. | --- | --- | 3x12 |
| 7.0 | 9.0 | 2 IN. | 9.0 | 2 IN. |
9.0 | 3 IN. | |||||
| 14.0 | 12.0 | 3 IN. | 12.0 | 3 IN. | 12.0 | 3 IN. | |||||
| OVER 10 UP TO 15 |
4 | 3.5 | 6.0 | 2 IN. | 6.0 | 2 IN. | 6.0 | 3 IN. | --- | 3x12 | --- |
| 7.0 | 8.0 | 3 IN. | 8.0 | 3 IN. | 8.0 | 3 IN. | |||||
| 14.0 | 10.0 | 3 IN. | 10.0 | 3 IN. | 10.0 | 3 IN. | |||||
| OVER 15 UP TO 20 |
4 | 3.5 | 5.5 | 2 IN. | 5.5 | 2 IN. | 5.5 | 3 IN. | 3x12 | --- | --- |
| 7.0 | 6.0 | 3 IN. | 6.0 | 3 IN. | 6.0 | 3 IN. | |||||
| 14.0 | 9.0 | 3 IN. | 9.0 | 3 IN. | 9.0 | 3 IN. | |||||
| OVER 20 | For
applications other than those listed in the tables, refer to CFR
1926.652(c)(2) for use of manufacturer's tabulated data. |
||||||||||
*Consult product manufacturer and/or qualified engineer for Section Modulus of available wales.